Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller

Product Details
Customization: Available
Type: Float
Material: Plastic
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller
  • Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller
  • Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller
  • Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller
  • Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller
  • Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller
Find Similar Products

Basic Info.

Model NO.
DF-96A/B/C
Certification
CE
Customized
Non-Customized
Power Indication
220V/50Hz
Output Indication
220V/20A
Category
Flow Sensors
Rated Voltage
220V/380V
Installation Method
Wall-Mounted
Origin
Zhejiang, China

Product Description

Automatic Liquid Switch protection automatic water level controller Pump Controller
Single-control UP pool (water storage) installation instructions shown in figure 1
Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller

A(red)-Upper water level control point. When water level gets to A point,

the probe touch water and controller can stop the pump by auto.

B(blue)-Lower water level control point. When water level gets off B point,

the probe out of reach water and controller can start the pump by auto.

C(black)-Should be placed in bottom of pool as the common line.

D(green) and E(yellow)are connected with C (black).

Single-control DOWN pool(drain water)installation instructions shown in figure 2.

Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller

E-Upper water level control point. When water level gets to E point,

the probe touch water and controller can start the pump by auto.

D-Lower water level control point. As liquid level gets off D point,

the probe out of reach water and controller can stop the pump by auto.

C-Should be placed in bottom of pool as the common line.

A&B-disconnected

1 . Lack of water protection installation instructions shown in figure 3.

Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller

C&D-Lower water level control points. When water level gets off this point,

C or D probe out of reach water and controller can stop the pump by auto.

E&C-short-connected;

A&B-disconnected

2 . Joint control UP and DOWN pool installation instructions shown in figure 4.

Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller

A-Upper water level control point in UP pool. When water level gets to A point,the probe touch water and controller can stop the pump by auto.

B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.

C-Should be placed in bottom of UP and DOWN pools as the common line.

D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.

E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected

Automatic Liquid Switch Protection Automatic Water Level Controller Pump Controller

Used to solve problem

1. On power but no work:

a. Check the red indicator is on or not. If not, make the connection is good enough;

2. When water level is above or below probes but the pump does not start or stop by auto, Please check it like the following.

a. Whether the probe is placed too high or low so that water level can reach or out of reach it;

b. The connection of upper &lower line or probe is dislocation by error or short connected;

c. To check the probe whether it is rust or not or the connection is good enough.

d. C- Check the common line whether it is placed in the lowermost bottom of pool.